Reverse osmosis membrane scale inhibitor, referred to as reverse osmosis scale inhibitor, is a kind of membrane scale inhibitor dispersant used in reverse osmosis water treatment system. After long-term reasonable use, it can effectively improve the quality and output of water production, extend the cleaning cycle and service life of the membrane, and reduce the production and operation costs of enterprises. Jiaming Water Treatment Technology reverse osmosis membrane scale inhibitor can be customized and produced according to the results of water quality inspection and analysis, Provide free on-site investigation and water sample extraction, free water quality detection and analysis, free sample trial, and comprehensive technical support and services.

The principle of reverse osmosis technology is to separate other substances from water based on the fact that they cannot penetrate the semi permeable membrane under the effect of higher than the osmotic pressure of the solution. Because the pore diameter of the reverse osmosis membrane is very small (only about 10A), it can effectively remove dissolved salts, colloids, microorganisms, organics, etc. in the water (removal rate up to 97% - 98%). Reverse osmosis is the most widely used desalination technology in high-purity water equipment at present. Its separation object is the organic matter with ionic range and molecular weight of several hundred in the solution; Reverse osmosis (RO), ultrafiltration (UF), microporous membrane filtration (MF) and electrodialysis (EDI) belong to membrane separation technologies.
The reverse osmosis membrane scale inhibitor can be customized according to the water quality detection and analysis results. The reverse osmosis scale inhibitor BT0110 commonly used by Jiaming Water Treatment Technology is introduced as follows.
Jiaming reverse osmosis scale inhibitor BT0110 is a scale inhibitor/dispersant used for membrane scale inhibition of broad-spectrum and high-efficiency reverse osmosis equipment, scale inhibitor BT0110 product is a high-efficiency liquid reverse osmosis membrane scale inhibitor, which is used to control the scale deposits in the membrane separation system and effectively control the scale of calcium carbonate, calcium silicate and calcium sulfate. It has high scale inhibition efficiency and does not form insoluble polymers with residual organic coagulants. Prevent scaling in reverse osmosis (RO), nanofiltration (NF) or ultrafiltration (UF) systems without ion exchange pretreatment, improve water yield and quality, and reduce operating costs.
Types of membranes applicable to Jiaming high-efficiency reverse osmosis scale inhibitor BT0110: high-efficiency reverse osmosis scale inhibitor BT0110 is applicable to Dow Filmtec, Hydranautics, Fluid Systems, TORAY, CSM, JOZZON, E-MEM, Vonton Keensen and other imported domestic membranes and various types of systems are used for scale inhibition dispersion.
Product features
(1) It can be used together with organic flocculant;
(2) It can be used to produce drinking water;
(3) Effectively control the scaling of calcium carbonate, calcium sulfate, barium sulfate and strontium sulfate, and prevent scaling when the L.S.I value reaches 3.0;
(4) All main reverse osmosis membranes can be used;
(5) Clean reverse osmosis membrane surface is maintained by dispersing blocking particles;
(6) The influent PH is valid within the range of 5~9;
(7) It can be added directly without dilution or after dilution;
(8) Good resistance to aluminum and iron oxides.
Technical indicators:
Appearance: pale yellow transparent liquid
PH value (1% aqueous solution): 2.5 ± 1.0
Density (20 ℃) g/cm ³: 1.10±0.05
Usage requirements
Dosing: the reverse osmosis scale inhibitor BT0110 product is continuously added into the water inlet before entering the membrane system. The typical dosage is 3-5 mg/l, which varies depending on the chemical properties of water, membrane type and system operating parameters (such as recovery rate, temperature and pressure). The specific dosage shall be calculated by the service provider.
Dilution: The reverse osmosis scale inhibitor BT0110 product should be added continuously. It is recommended to dilute it with RO water or desalted water, and the dilution ratio should not exceed 10.
Note: too high or insufficient dose will cause membrane pollution.
Packaging and storage
Plastic drum, net weight 25kg/drum; Shelf life: keep in a dark and cool place, valid for 2 years.
Safety and protection
Wear latex gloves, protective glasses and protective clothing. In case of splashing eyes, please immediately flush eyes with plenty of water and seek medical advice quickly. Avoid spilling on the cement floor to avoid corrosion. If it erodes the floor, please wash it with clean water immediately.

The reverse osmosis membrane scale inhibitor can be customized according to the water quality detection and analysis results. Welcome to visit us. Jiaming Water Treatment Technology (Shanghai) Co., Ltd. is composed of dozens of well-known experts and technologies with more than 20 years of experience in the water treatment agent and equipment industry. With strong financial and technical strength and rich application experience, Jiaming Water Treatment Technology has created a well-known brand in the water treatment industry.